Washington Mechanical HVAC & Fuel Thermodynamics
Washington Cold-Climate Heat-Pump vs. Furnace Payback Calculator
Pre-loaded with Washington's residential electric tariff (11.6¢/kWh), pipeline natural gas rate ($1.52/therm), regional propane ($2.95/gal), #2 heating oil ($4.05/gal), and 4,680 annual heating degree days (99% winter design temperature: 23°F).
Envelope, COP & Fuel Inputs
Mechanical COP vs. combustion AFUE model
| Heating Equipment & Efficiency | Unit Tariff | Cost / MMBtu | Est. Annual Heating Bill |
|---|---|---|---|
| Cold-Climate Heat Pump — COP 2.8 (~8.5 HSPF2) | 11.6¢/kWh | $12.14 | $859/yr |
| Cold-Climate Heat Pump — COP 3.3 (~10.1 HSPF2) | 11.6¢/kWh | $10.30 | $729/yr |
| High-Spec Inverter Heat Pump — COP 3.8 (~11.6 HSPF2) | 11.6¢/kWh | $8.95 | $633/yr |
| Atmospheric Natural Gas Furnace — 80% AFUE | $1.52/therm | $19.00 | $1,344/yr |
| Condensing Natural Gas Furnace — 95% AFUE | $1.52/therm | $16.00 | $1,132/yr |
| Delivered Propane Furnace — 90% AFUE | $2.95/gal | $35.84 | $2,536/yr |
| #2 Heating Oil Furnace/Boiler — 85% AFUE | $4.05/gal | $34.40 | $2,434/yr |
| Year | Heat-Pump Bill | Furnace Bill | Annual Fuel Delta | Cumulative Net Position |
|---|---|---|---|---|
| Year 1 | $729 | $1,344 | +$615 | -$5,585 |
| Year 2 | $747 | $1,378 | +$631 | -$4,954 |
| Year 3 | $766 | $1,413 | +$647 | -$4,307 |
| Year 4 | $785 | $1,448 | +$663 | -$3,644 |
| Year 5 | $805 | $1,484 | +$679 | -$2,965 |
| Year 6 | $825 | $1,521 | +$696 | -$2,268 |
| Year 7 | $845 | $1,559 | +$714 | -$1,555 |
| Year 8 | $867 | $1,598 | +$732 | -$823 |
| Year 9 | $888 | $1,638 | +$750 | -$73 |
| Year 10 | $910 | $1,679 | +$769 | +$696 |
Thermodynamic Equivalence & Sizing Notes for Washington
One million BTU (1 MMBtu) equals 293.071 kWh of electrical energy, 10.0 therms of pipeline natural gas, 10.93 gallons of HD-5 propane, or 7.22 gallons of #2 distillate fuel oil. In Washington (23°F ASHRAE 99% winter design temperature), verify ACCA Manual J block heat loss and cold-weather compressor capacity maintenance at design outdoor dry-bulb temperature before eliminating auxiliary heat strips or dual-fuel backup.
Related Washington County & Building-Envelope Ledgers
Explore Washington State Hub · Washington Roof Cost & Lifespan Calculator · County Property Tax Calculators: Clark County · King County · Pierce County · Snohomish County · Spokane County · Thurston County
Frequently Asked Questions: Washington Heat-Pump Economics
Is a heat pump cheaper to run than a natural gas furnace in Washington?
At Washington's residential averages of 11.6 cents/kWh for electricity and $1.52/therm for natural gas, a cold-climate heat pump operating at a seasonal COP of 3.3 delivers space heat at $10.30/MMBtu, compared with $19.00/MMBtu for an 80% AFUE gas furnace and $16.00/MMBtu for a 95% AFUE condensing gas furnace.
How fast does a heat pump pay back against propane or heating oil in Washington?
Delivered propane ($2.95/gal at 90% AFUE = $35.84/MMBtu) and #2 heating oil ($4.05/gal at 85% AFUE = $34.40/MMBtu) carry substantially higher unit thermal costs than pipeline gas in most states. Against 90% AFUE propane in Washington, a 3.3 COP heat pump changes annual fuel spend by $1,807/yr on a 2,100 sq ft home.
How does the federal IRS Section 25C heat-pump tax credit work?
Under Internal Revenue Code Section 25C (Energy Efficient Home Improvement Credit), qualifying Air-Source Heat Pumps meeting Consortium for Energy Efficiency (CEE) highest-efficiency tiers qualify for a nonrefundable federal tax credit equal to 30% of installed equipment and labor cost, capped at $2,000 per taxpayer per year.