FTC Disclosure & Editorial NoticeHearth & Ledger publishes independent residential tax, thermodynamic, and building-envelope models. If partner quote links are enabled, we may earn a referral fee at zero cost to homeowners; formulas and county tables are never altered by sponsors. Read Full Disclosure →
Electricity Tariff 31.8¢/kWh California residential avg
Natural Gas Rate $2.18/therm 100,000 BTU per therm
Heating Climate 2,140 HDD Design winter: 36°F
IRS Sec. 25C Cap $2,000 30% of qualified heat pump

Envelope, COP & Fuel Inputs

Mechanical COP vs. combustion AFUE model

sq ft
¢/kWh
$ $/therm
$
$
Delivered Heat Cost $28.24/MMBtu vs. $27.25 (Natural Gas 80% AFUE)
Annual Fuel Delta -$32/yr $914 HP vs. $882 furnace
Net Incremental Capital $6,500 After $2,000 Sec. 25C credit
Simple Break-Even No Fuel Payback 32.4 MMBtu/yr space-heat load
California Cross-Fuel Delivered Heating Cost Benchmark (32.4 MMBtu/yr Load)
Heating Equipment & Efficiency Unit Tariff Cost / MMBtu Est. Annual Heating Bill
Cold-Climate Heat Pump — COP 2.8 (~8.5 HSPF2) 31.8¢/kWh $33.28 $1,077/yr
Cold-Climate Heat Pump — COP 3.3 (~10.1 HSPF2) 31.8¢/kWh $28.24 $914/yr
High-Spec Inverter Heat Pump — COP 3.8 (~11.6 HSPF2) 31.8¢/kWh $24.53 $794/yr
Atmospheric Natural Gas Furnace — 80% AFUE $2.18/therm $27.25 $882/yr
Condensing Natural Gas Furnace — 95% AFUE $2.18/therm $22.95 $743/yr
Delivered Propane Furnace — 90% AFUE $3.45/gal $41.92 $1,356/yr
#2 Heating Oil Furnace/Boiler — 85% AFUE $4.25/gal $36.10 $1,168/yr
10-Year Escalating Cash-Flow Schedule (Assumes 2.5%/yr Tariff Escalation)
Year Heat-Pump Bill Furnace Bill Annual Fuel Delta Cumulative Net Position
Year 1$914$882-$32-$6,532
Year 2$937$904-$33-$6,565
Year 3$960$926-$34-$6,599
Year 4$984$950-$35-$6,633
Year 5$1,009$973-$35-$6,669
Year 6$1,034$998-$36-$6,705
Year 7$1,060$1,023-$37-$6,742
Year 8$1,086$1,048-$38-$6,780
Year 9$1,113$1,074-$39-$6,819
Year 10$1,141$1,101-$40-$6,859

Thermodynamic Equivalence & Sizing Notes for California

One million BTU (1 MMBtu) equals 293.071 kWh of electrical energy, 10.0 therms of pipeline natural gas, 10.93 gallons of HD-5 propane, or 7.22 gallons of #2 distillate fuel oil. In California (36°F ASHRAE 99% winter design temperature), verify ACCA Manual J block heat loss and cold-weather compressor capacity maintenance at design outdoor dry-bulb temperature before eliminating auxiliary heat strips or dual-fuel backup.

Related California County & Building-Envelope Ledgers

Explore California State Hub · California Roof Cost & Lifespan Calculator · County Property Tax Calculators: Alameda County · Contra Costa County · Fresno County · Kern County · Los Angeles County · Orange County · Riverside County · Sacramento County

Frequently Asked Questions: California Heat-Pump Economics

Is a heat pump cheaper to run than a natural gas furnace in California?

At California's residential averages of 31.8 cents/kWh for electricity and $2.18/therm for natural gas, a cold-climate heat pump operating at a seasonal COP of 3.3 delivers space heat at $28.24/MMBtu, compared with $27.25/MMBtu for an 80% AFUE gas furnace and $22.95/MMBtu for a 95% AFUE condensing gas furnace.

How fast does a heat pump pay back against propane or heating oil in California?

Delivered propane ($3.45/gal at 90% AFUE = $41.92/MMBtu) and #2 heating oil ($4.25/gal at 85% AFUE = $36.10/MMBtu) carry substantially higher unit thermal costs than pipeline gas in most states. Against 90% AFUE propane in California, a 3.3 COP heat pump changes annual fuel spend by $442/yr on a 2,100 sq ft home.

How does the federal IRS Section 25C heat-pump tax credit work?

Under Internal Revenue Code Section 25C (Energy Efficient Home Improvement Credit), qualifying Air-Source Heat Pumps meeting Consortium for Energy Efficiency (CEE) highest-efficiency tiers qualify for a nonrefundable federal tax credit equal to 30% of installed equipment and labor cost, capped at $2,000 per taxpayer per year.